FBS6
Insulated Fire Curtains
Fireblind™ FBS6 - Automatic Insulated Fire Curtains
The Fireblind™ FBS6 automatic insulated fire curtain Single roller systems, up to 6metres wide, have been certified to BS EN 1634-1:2000, PAS 121:2007 and have a rating of 88 minutes integrity & 88minutes Insulation at 1000 degrees Celsius.
Fire curtains can drop in stages (split drop delay) to provide progressive smoke containment. They can therefore be used as automatic smoke curtains and are fully tested to BS 1634-3:2004 and to the latest BS requirements that systems must fall to their fire operational position in a safe and controlled manner even in the event of a Total Power failure.
Split drop delay functions can provide temporary means of escape and are therefore a critical life safety requirement.
Fire curtains require side guides to provide a seal between the fabric and the structure of the building. A fire will cause either positive or negative pressures, these pressures can cause a curtain to act like a sail and pull the curtain fabric out of the side guides. Therefore a fabric retaining system is used to prevent this occurring.
Control Panels (C P). These are necessary to control the motors and co-ordinate all functions of the curtain and to relate to the fire / smoke alarm system. In normal operation the C P provide a 24v supply to the curtain motors, the curtains will be in the retracted mode. Should smoke be detected, the fire alarm contact in the C P will be opened by the fire alarm control system, the C P will remove the 24v supply to the curtain motors and the curtains will descend under the power of gravity in a controlled manner. As soon as the fire alarm system is reset the C P will reinstate the 24v supply to the curtain motors and the curtains will retract. Each C P will be supplied with a 24v battery, this will enable full control of the system should the mains power fail.
Benefits
Certified to BS EN 1634-1:2000, PAS 121:2007.
Have a rating of 88 minutes integrity & Insulation at 1000 degrees Celsius.
Split drop delay functions can provide temporary means of escape.
Product Range
FBS1
The FIREBLIND™ FBS1 fire curtain is an electrically operated automatic fire curtain designed for it's fire resistant qualities.....more
FBS2
The FIREBLIND™ FBS2 smoke curtain is an electrically operated automatic fire curtain designed to restrict the lateral spread of smoke within a building.....more
FBS3
Residential Fire Curtains / Smoke Curtains
The FIREBLIND™ FBS3 Marian Fire & Smoke residential fire curtain / smoke curtain has been specially designed and developed for the home and is suitable for new build and refurbishments .....more
FBS4
The FIREBLIND™ FBS4 steel fire shutter is a fire rated rolling shutter, ideal for offices, schools and public buildings .....more
FBS5
The FIREBLIND™ FBS5 fire rated steel door is available in a full range of specifications and dimentions tailored to your specific requirements .....more
FBS6